Data is below and pictures are attached, I think I have included everything if not please let me know. Concrete Labs: Slump test - 0.3 water/cement ratio, see pictures attached – it’s a shear slump which has no slump value. Concrete compression Cube peak stress peak load 1 19.75MPa 194.5kN 2 17.41MPa 174.1kN 3 17.15MPa 171.5kN Steel Tensile test: Original length – 25mm Original diameter – 5mm Failure length – 32.055 Failure Diameter – 3mm See pictures attached for graph. Aluminium Tensile test: Original length – 25mm Original diameter – 5mm Failure length – 32.276 Failure Diameter – 3.2mm